Dry Cooling Towers
Product Specifications:
| Model Number | DCT |
|---|---|
| Place Of Production | INDIA |
| Production Brand Name | GEM |
| Certifications | ISO |
| Terms Of Payment | T/T |
| Supply Ability | UPTO CUSTOMER'S REQUIREMENT |
Description Of Dry Cooling Towers
DRY COOLING TOWER is an equipment which is used to cool and maintain the temperature of process hot water at a particular level. This operates on the principle of heat transfer by a hear exchanger with extended fins. This fan is driven by an Electric motor.Technical Specifications
Copper Tubes The vital factor-only the best quality imported (5 / 8") OD copper tubes in Level Wound Coils (LWC) are used. This ensure coils with the minimum number of joints by forming a hair pin bends as well as to form a uniform wall thickness that eliminates embarrassing and expensive leaks after installation. Tubes are staggered in the path of airflow for better heat transfer efficiency.
Return Bends They are die-formed from thick walled tubing that is heavier than the standard tubing used in the rest of the coils. This provides the toughness and durability required in the most vital parts of the coils.
Headers Inlet and outlet headers are constructed of heavy wall steel pipes with shoulders formed at each brazed connection to the 5 / 8" tube in the coil. This shoulders intruded with special tooling provides the strength to the brazed joint that eliminates another source of leak during transit and installation.
Mechanical Tube Expansion Tubes are between tube and fin. This positive and controlled expansion procedure provides a clean, smooth inner tube surface for allow water pressure drop and guarantees uniform heat transfer between tube.
Heat Transfer Coils
Improved Circuiting-The GEM COOLING TOWER DESIGN of water circuiting provides flexibility in selection and unequaled performance optimization. All inlet and outlet connections are provided on the same end thus reducing expansion and installation.
Rigid Construction-A die formed galvanized steel frame provides stacking and shipping support and protection against tube damage during expansion and installation.
Venting and Draining-Each water duty coil is provided with a convenient vent connection at the highest point and a drain connection at the lowest point.
Pressure Testing-Each coil is pressure tested after manufacture, by air under water at 300 psi for water application.
Computerized selection-Speeds up and simplify the selection of right coil for your specific requirement.